- RainDance Water Systems WH-RO SERIES
- Diamond Plate Skid
Mount Whole House Reverse
Osmosis Water Filtration System
-
- (appearances may vary,
300gal. storage tank shown)
- Welcome to RainDance Water
Systems
-
- RainDance Water Systems offers
turnkey state of the art whole house reverse osmosis systems
of unparalleled performance.
Efficiency, durability and ease
of maintenance are key characteristics of our WH-RO water treatment
equipment. Our WH-RO systems are highly flexible, allowing us
to customized and cater to the full spectrum of whole house,
business and agricultural applications ranging from the production
of 500 gallons of water per day to 25,000 gallons of water per
day.
- Contrary to many of our competitors,
who sell only one standard water product. We understand that
municipal and well water sources can differ and focus solely
on user friendly with the ability to customize our water systems
based on your water chemistry. We feel, RainDance Water Systems
offers simply the best there is in this demanding and highly
specialized filtration business.
-
-
- RAINDANCE WATER SYSTEMS WH-RO
WHOLE HOUSE R.O. EZ-INSTRUCTIONS
-
- The RainDance Water Systems
WH-RO installation instructions and maintenance procedure listed
on this webpage are provided to give our customers an understanding
of the ease of installing and maintaining our water treatment
products. Moreover, our WH-RO Series RO systems are pretested
before shipping, user friendly, and components are shipped pre-plumbed
on the skid and in most cases unit only requires a 120 volt 1
phase 60 Hz power source or 230 volt single or three phase power
source at customer option. Our WH-RO state of the art skid mount reverse
osmosis is plumbed and pre wired in most cases with one inlet
connection, one drain connection, one water use connection, and
one electrical connection to allow for fast hassle free installation.
From the delivery of the equipment to your home or facility to
the set up and use of water - In hours not days!
-
- Disclaimer: These are basic sample instructions
for our WH-RO Series and are intended for reference only. Installation
and maintenance can vary. Each WH-RO unit will have their own
customized instructions specific to each customer. If your system
is designed with custom or special features such as PLC controller,
pH correction, 220v, antiscalant pretreatment, or other we will
include additional installation instructions.
-
-
- 1. Preliminary.
a. Please review the hydraulic and electrical diagrams that have
been supplied.
b. Save the enclosed information on all of the components and
devices (meters, pumps, switches, etc) that have been supplied.
They may need referral to for making adjustments and also for
service and replacement in the future.
c. Be sure that the unit is paced in an area where freezing will
not occur and that is not in direct sunlight.
d. Place unit on a hard level surface that will support a wet
weight (exclusive of storage tanks) of 1,000 pounds.
e. Place unit within 20 feet horizontal and 10 feet vertical
of a drain that is to all applicable local codes and can withstand
a constant water flow of 5.0 USGPM without overflow.
f. Place unit within 10 feet of a fused 120 volt 1 phase 60 Hz
power supply adequate for 15 amps with everything running. Another
plug-in 120 volt outlet is also needed. This will supply power
to the Maxi-cure and to the UV light.
g. A water supply to the unit must be available that has the
following characteristics:
1. Flow of 5.0 GPM at a pressure of 20 to 60 PSI.
2. Temperature from 40 to 100 degrees F.
3. Hardness, pH and alkalinity combined for a Langelier's Saturation
Index not to exceed +1.6 OR softened water.
4. No iron bacteria.
5. Only trace amounts of Hydrogen Sulfide.
- h. Place storage tanks with
a minimum 1" diameter bottom outlet within 5 feet of the
unit.
-
- 2. Installation.
a. Connect water supply to the fitting marked INLET.
b. Connect the fitting from the RO section marked DRAIN to the
main drain. Use ½" rigid or flexible tubing. Max.
flow will be 5 GPM.
c. Connect the fitting marked PRODUCT to the top tank fitting
marked PRODUCT with same size tubing as the drain.
d. Connect the storage tank(s) to the inlet of the re-pressure
pump marked PUMP INLET. Use RIGID PIPE at least 1" to avoid
any chance of a vacuum collapse.
e. Connect the fitting (1" FPT) to the household line(s)
to be serviced with RO water. It is marked TREATED WATER.
f. Connect the power lines from the control box to the above
mentioned fused supply using local code connections. Be sure
that the fuse/breaker is in the off position while making this
connection.
g. Connect the power supply for the U.V. light and Maxi Cure
to a standard 15-amp 120 volt 60 Hz 1 phase outlet.
h. Connect the three colored wires at the control box to the
matching colored wires from the tank floats at the top of the
tank. These wires are 24-volt transformer isolated control wires.
i. Connect the wires marked PUMP LEVEL to the two wires from
the lower float in the tank that prevent dry-running of the re-pressure
pump. These wires are 24-volt transformer isolated control wires.
j. Double check all connections and then proceed to start-up
and run section.
-
- 3. Start-up and run.
- a. With water OFF apply power
ONLY to the light bar on the back of the unit where the UV and
the Maxi-cure are plugged in. See g. above. DO NOT apply the
120 volt power to the system through the fuse / circuit breaker
used.
b. Unplug the UV light.
c. Refer to the instructions for the maxi-cure. When the start-up
of the maxi-cure is complete and the unit is in the service position,
OPEN the outlet of the maxi-cure by-pass valve and allow the
system to pressurize.
d. Correct any initial leaks. NOTE: The system was tested prior
to shipment and was leak-free as shipped. Some leaks may be created
during transit.
e. Please note the inlet solenoid valve to the right of the two
blue cartridge filters. Note the wires going to a coil on the
top of this valve. Turn the coil ¼ turn counter clockwise
--- there is a small lever on the coil to make this easy.
f. Water will begin to flow into the unit to rid it of air. Allow
water to flow for a few minutes.
g. Turn the coil clockwise finger tight until water flow ceases.
h. Put the switch marked ON/OFF on the side of the gray control
panel to the OFF position.
i. Turn on the 120 volt supply
j. Turn on the ON/OFF switch on the side of the gray control
box.
k. The green panel light will glow.
l. After a few moments the pump marked P1 will start.
m. As water begins to flow into the storage tank(s) adjust the
valve marked DRAIN VALVE until the flow to drain in the meter
marked DRAIN METER is equal to or 10% higher than the flow in
the meter marked PRODUCT METER.
n. Adjust the valve marked RE-CIRC. VALVE until the gauge marked
SYSTEM PRESS. Reads 150 to 220 PSI.
o. Continue adjusting the drain and re-circulation valves until
the system pressure is stable and the drain flow is equal to
or 10% higher than the product flow.
p. When water in the storage tank(s) reaches the level of the
bottom tank float, the re-pressure pump will start and draw water
from the tank(s) and then shut off when the house pressure gauge
reaches approximately 50 PSI.
q. Allow some water to flow into the system (open a house faucet)
to fill the UV chamber and bleed the system of air.
r. Plug-in the UV light and the TDS monitor. Review the monitor
instructions and set accordingly. Note the light on light for
the UV ballast.
s. Re-check the entire system for leaks and correct as needed.
-
- t. Record the following information.
This will be extremely important in the future to diagnose problems
and replace filters as needed:
1. Product flow. _________GPM
2. Drain Flow ___________GPM
3. System Pressure _______PSI
4. TDS of product water _________PPM
5. Pressure on small gage marked G1 _________PSI
6. Pressure on small gage marked G2__________PSI
7. Pressure difference G2 minus G1 ________PSI
8. Approximate temperature of water to unit ________deg. F.
-
- 4. Maintenance:
-
- 1. Add 3 drops of oil to P1
at points indicated every 2 -4 weeks.
2. When pressure difference between G2 minus G1 increases by
more than 5 PSI above the initial reading replace the filter
marked 5 MIC.
3. Check and adjust the drain and re-circulation valves daily
for the first week and then every week after that.
4. When TDS increases by more than 20% from the above with no
corresponding change in raw water TDS clean or replace the RO
element(s).
5. Replace the Cartridge marked CARBON BLOCK every 4 months
6. If water production through the product flow meter drops by
more than 15% without a reduction in inlet water temperature
or a drop in operating pressure, clean or replace the RO element(s).
- 5. Replace the UV bulb every
12 months
- Unmatched WH-RO Series
Standard Features
-
Our state of the art WH-RO
whole house reverse osmosis systems includes:
- All components (excluding
storage tank) located and
contained on our beautifully polished skid mount aluminum diamond
plate platform with wheels - for easy positioning.
- Approx. System dimensions: 25"W
x 48"L x 61" high (500gpd -5000gpd) Designed to fit
through most standard door ways.
- Approx. System dimensions: 34"W
x 96"L x 75" high (6000gpd -25000gpd) Designed to fit
through most standard door ways.
- Includes the chemical and salt
free Maxi-Cure reverse osmosis pre-treatment system. The Maxi-Cure
provides protection for the RO membrane against hard water, iron,
manganese, hydrogen sulfide gas, suspended solids, chlorine and
more.
- Treated water from our WH-RO
Series is guaranteed to meet the EPA Secondary Drinking Water
Standards of 500ppm or less.
- Automatic Flush on start up
- Fast flushes membrane each time the unit starts.
- Includes a programmable logic
controller (PLC), electronic sensors can monitor all vital
functions of the system including flow, pressure, tank levels,
water quality, filter condition, membrane condition, and electrical
supply. The control system automatically responds to changes
in these variables, initiating the proper response to virtually
any operating condition. A user friendly easy to read (English
Only) centrally-located operator interface is provided to simplify
system control. The PLC displays all operating conditions and
tells you what the unit is doing at any time. Perfect for serviceman,
maintenance person, or do it yourselfer.
- Includes 1- 20" BB sediment
prefilter to remove dirt and sediment
- Includes 1- 20" BB carbon
prefilter
- Includes a Thin Film Composite
Membrane. Rejection rate (98% +). High feed water recovery
rate (50% +).
- Includes Liquid Filled Pressure
Gauge.-Measures system's operating pressure.
- Includes Low Pressure Switch.
- Includes Prefilter Gauge.
Measures pressure drop & indicates filter change required.
- Includes High Pressure Switch.
Safety mechanism to aviod equipment damage.
- Includes TDS monitor with alarm
-TDS meter has a light that glows if TDS is above a set limit
- Includes 1- 35" dia. x
81" ht. 300 gallon storage tank. For ease of handling and
ability to get through doors we use a multiple array of tanks
for larger households.
- Includes 3 electronic float
switches for storage tank - Top tank for shut-off, one 1Ft. lower
for turn on, and one at bottom for control of re-press. pump.
- Includes 12gpm @ 50psi fully
automatic electric pump (constant pressure) re-pressure system
- Draws water out of the storage tank.
- Includes a chemical free ultraviolet
UV system.SPV-15
UV Ultraviolet Disinfection carries NSF/ANSI Standard 55, Class
A Certification. These units are ideal for use in any disinfection
application where a third-party validated unit is specified.
- Each skid mount reverse osmosis
is fully assembled and tested before it leaves the plant.
- For optimum WH-RO Series performance
customers must have at least 7gpm @ 30psi available. Note: Our
WH-RO Series contains complete pretreatment for chlorine and
hard water (calcium) typically associated with municipal water
sources. If WH-RO is to be used on well water we offer the following
guidelines: Operating Parameters: Max TDS-3500ppm, Total iron is less than
5ppm, Manganese is less than 3ppm, H2S less than 10ppm, Water
hardness below 30gpg,
pH 6.5 -8.5,
No iron bacteria. Calculations of production capabilities are
based on a feed water temperature of 60 Deg. F. Lower temperatures
may result in slightly lower production levels.
- Unlike most
companies , we are able to tailor our WH-RO systems to your needs.
To ensure the longest trouble free system life and best possible
treated water quality, we encourage you to fax (760-896-6999)
or E-mail your water chemistry
report or let us know the name of your municipal water district
provider. You may also send us a water sample for evaluation.
- New Standard Feature as of 9-1-2006 (normally an add-on option)
we now include our built-in skid mount pH neutralizer system
at no extra charge. Designed to keep your ro water non-corrosive.
- FREE SHIPPING ON ALL WH-RO
SKID REVERSE OSMOSIS WITHIN THE CONTINENTAL UNITED STATES.
For complete pricing
and information on our WH-RO whole house skid mount reverse osmosis
system please return to our WH-RO
Home Page > HERE
- Custom water treatment designing
- We have
the expertise to custom design any water treatment system to
fit your application needs. Wall mounted, skid mounted, horizontal,
vertical, diamond plate, stainless steel, portable, high pressure,
low pressure. In most cases systems are pre-wired and pre-plumbed
for easy installation. Complete export capabilities and installation
available.
Our customers include numerous
companies, manufacturers, cattle & dairy farms, and households
around the world - United States, Japan, Canada, Taiwan, Indonesia,
Malaysia, United Kingdom, Cayman Islands, and the Bahamas who
require water treatment and pure water applications.
RainDance Water
Systems customers include: The United States Coast Guard, Washington
St. National Park Service, San Diego State University, Palomar
College, Quinlan Texas Elementary School, Hunter Industries,
Sonance Corp., Owens Brigam Medical, 1st Choice GMAC Realty,
Century 21 Realty, Austin Productions, Fairfield Country Club,
and Auer Precision Inc. just to name a few.
RainDance
Water Systems
- Proud Member
Of The Ramona Chamber of Commerce
- Technical Support
Available for all of our U.S. & Overseas Customers
- Free Inorganic
Water Testing
- Full Export
Capabilities
- Call Toll Free
1-877-788-8387
- FAX 760-896-6999
|
- RainDance Water
Systems P.O. Box
2312 Ramona, Ca. 92065
- U.S. Toll Free: 1-877-788-8387
/ Outside The U.S. 760-788-8387
-
- For complete pricing
and information on our WH-RO whole house skid mount reverse osmosis
system please return to our WH-RO
Home Page > HERE
Copyright 1996 RainDance Water Systems. All rights reserved
|